Brand |
: |
Lovato |
MFR # |
: |
P1RD2P63A300 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
2 |
Range |
: |
P1RD2P |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF202001R1630 F202 AC-63/0,03 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
2 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Series |
: |
F200 |
Mounting Style |
: |
DIN Rail Mount |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD2P63A030 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
2 |
Range |
: |
P1RD2P |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230V ac |
Series |
: |
P1RD |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9R11225 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
25A |
Number of Poles |
: |
2 |
Range |
: |
Multi9 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
240V ac |
Series |
: |
ID |
Mounting Style |
: |
DIN Rail Mount |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD4P63A300 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
4 |
Range |
: |
P1RD4P |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230 or 400V ac |
Series |
: |
P1RD |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9R11440 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
4 |
Range |
: |
Multi9 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
415V ac |
Series |
: |
ID |
Mounting Style |
: |
DIN Rail Mount |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD4P63A030 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
4 |
Range |
: |
P1RD4P |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230 or 400V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF204001R1900 F204 AC-100/0,03 |
Circuit Breaker Type |
: |
RCD |
Current Rating |
: |
100A |
Number of Poles |
: |
4 |
Range |
: |
System Pro M Compact |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Series |
: |
F200 |
Mounting Style |
: |
DIN Rail Mount |
Rated AC Voltage |
: |
400V |
Break Time |
: |
Instantaneous |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD2P25AC300 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
25A |
Number of Poles |
: |
2P |
Range |
: |
P1 |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230V ac |
Series |
: |
P1RD |
|
Brand |
: |
Europa |
MFR # |
: |
EUR140.100/2A |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
2 |
Range |
: |
EUR1 |
Trip Sensitivity |
: |
100mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230V ac |
Series |
: |
EUR1 |
Mounting Style |
: |
DIN Rail Mount |
|
Brand |
: |
Europa |
MFR # |
: |
EUR140.100/4A |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
4 |
Range |
: |
EUR1 |
Trip Sensitivity |
: |
100mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230V ac |
Series |
: |
EUR1 |
Mounting Style |
: |
DIN Rail Mount |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD2P25AC030 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
25A |
Number of Poles |
: |
2P |
Range |
: |
P1 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF202001R3250 F202 AC-25/0,3 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
25A |
Number of Poles |
: |
2 |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type AC |
Series |
: |
F200 |
Mounting Style |
: |
DIN Rail Mount |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD4P25AC300 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
25A |
Number of Poles |
: |
4P |
Range |
: |
P1 |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230 V ac, 400 V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF202001R3400 F202 AC-40/0,3 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
2 |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type AC |
Series |
: |
F200 |
Mounting Style |
: |
DIN Rail Mount |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD4P25AC030 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
25A |
Number of Poles |
: |
4P |
Range |
: |
P1 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230 V ac, 400 V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF202401R1400 F202 A-40/0,03 AP-R |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
2 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230/400V ac |
Series |
: |
F200 |
Earth Leakage Protection Type |
: |
A |
Special Features |
: |
Earth Fault Safety Protection |
Mounting Style |
: |
DIN Rail Mount |
Rated AC Voltage |
: |
277V |
Break Time |
: |
Instantaneous |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD2P40AC300 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
2P |
Range |
: |
P1 |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF204201R2630 F204 A S-63/0,1 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
4 |
Trip Sensitivity |
: |
100mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230/400V ac |
Series |
: |
F200 |
Earth Leakage Protection Type |
: |
A |
Special Features |
: |
Earth Fault Safety Protection |
Mounting Style |
: |
DIN Rail Mount |
Rated AC Voltage |
: |
277V |
Break Time |
: |
Instantaneous |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD2P40AC030 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
2P |
Range |
: |
P1 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF204401R1630 F204 A-63/0,03 AP-R |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
4 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230/400V ac |
Series |
: |
F200 |
Earth Leakage Protection Type |
: |
AP-R |
Special Features |
: |
Earth Fault Safety Protection |
Mounting Style |
: |
DIN Rail Mount |
Rated AC Voltage |
: |
277V |
Break Time |
: |
Instantaneous |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD4P40AC300 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
4P |
Range |
: |
P1 |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230 V ac, 400 V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF204401R1250 F204 A-25/0,03 AP-R |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
25A |
Number of Poles |
: |
4 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230/400V ac |
Series |
: |
F200 |
Earth Leakage Protection Type |
: |
AP-R |
Special Features |
: |
Earth Fault Safety Protection |
Mounting Style |
: |
DIN Rail Mount |
Rated AC Voltage |
: |
277V |
Break Time |
: |
Instantaneous |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD4P40AC030 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
4P |
Range |
: |
P1 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230 V ac, 400 V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF204401R1400 F204 A-40/0,03 AP-R |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
4 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230/400V ac |
Series |
: |
F200 |
Earth Leakage Protection Type |
: |
AP-R |
Special Features |
: |
Earth Fault Safety Protection |
Mounting Style |
: |
DIN Rail Mount |
Rated AC Voltage |
: |
277V |
Break Time |
: |
Instantaneous |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD2P63AC300 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
2P |
Range |
: |
P1 |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230V ac |
Series |
: |
P1RD |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
A9R67640 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
1P+N |
Range |
: |
Acti9 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
220 → 240V ac |
Series |
: |
Acti9 iIG40 |
Overall Depth |
: |
85mm |
Overall Dimensions |
: |
36 x 74 x 85mm |
Earth Leakage Protection Type |
: |
AC |
Breaking Capacity at Maximum Voltage Rating |
: |
1500 A |
Overall Length |
: |
36mm |
Overall Width |
: |
74mm |
Mounting Style |
: |
DIN Rail Mount |
Rated AC Voltage |
: |
220 → 240V |
Break Time |
: |
Instantaneous |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF204401R1900 F204 A-100/0,03 AP-R |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
100A |
Number of Poles |
: |
4 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
277 V ac, 480 V ac |
Series |
: |
F200 |
Earth Leakage Protection Type |
: |
AP-R |
Special Features |
: |
Earth Fault Safety Protection |
Mounting Style |
: |
DIN Rail Mount |
Rated AC Voltage |
: |
277 V, 480 V |
Break Time |
: |
Instantaneous |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD2P63AC030 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
2P |
Range |
: |
P1 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF202199R1400 F202 A-40/0,03 110V |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
40A |
Number of Poles |
: |
2 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
110V ac |
Series |
: |
F200 |
Earth Leakage Protection Type |
: |
A |
Mounting Style |
: |
DIN Rail Mount |
Rated AC Voltage |
: |
277V |
Break Time |
: |
Instantaneous |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD4P63AC300 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
4P |
Range |
: |
P1 |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230 V ac, 400 V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF204001R3630 F204 AC-63/0,3 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
4 |
Trip Sensitivity |
: |
300mA |
Tripping Characteristics |
: |
Type AC |
Series |
: |
F200 |
Mounting Style |
: |
DIN Rail Mount |
|
Brand |
: |
Lovato |
MFR # |
: |
P1RD4P63AC030 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
4P |
Range |
: |
P1 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230 V ac, 400 V ac |
Series |
: |
P1RD |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF204001R1630 F204 AC-63/0,03 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
4 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Series |
: |
F200 |
Mounting Style |
: |
DIN Rail Mount |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
R9ERA263 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
2 |
Range |
: |
Resi9 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230V ac |
Series |
: |
R9E |
|
Brand |
: |
ABB |
MFR # |
: |
2CSF204201R4630 F204 A S-63/0,5 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
4 |
Trip Sensitivity |
: |
500mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230/400V ac |
Series |
: |
F200 |
Earth Leakage Protection Type |
: |
A |
Special Features |
: |
Earth Fault Safety Protection |
Mounting Style |
: |
DIN Rail Mount |
Rated AC Voltage |
: |
277V |
Break Time |
: |
Instantaneous |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
R9ERC263 |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
2 |
Range |
: |
Resi9 |
Trip Sensitivity |
: |
30mA |
Tripping Characteristics |
: |
Type AC |
Voltage Rating |
: |
230V ac |
Series |
: |
R9E |
|
Brand |
: |
Europa |
MFR # |
: |
EUR163.100/2A |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
63A |
Number of Poles |
: |
2 |
Range |
: |
EUR1 |
Trip Sensitivity |
: |
100mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230V ac |
Series |
: |
EUR1 |
Mounting Style |
: |
DIN Rail Mount |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
R9FS660 |
Circuit Breaker Type |
: |
RCBO |
Current Rating |
: |
60A |
Number of Poles |
: |
1 |
Range |
: |
Resi9 |
Trip Sensitivity |
: |
500mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
250V ac |
Series |
: |
R9F |
|
Brand |
: |
Europa |
MFR # |
: |
EUR180.100/4A |
Circuit Breaker Type |
: |
RCCB |
Current Rating |
: |
80A |
Number of Poles |
: |
4 |
Range |
: |
EUR1 |
Trip Sensitivity |
: |
100mA |
Tripping Characteristics |
: |
Type A |
Voltage Rating |
: |
230V ac |
Series |
: |
EUR1 |
Mounting Style |
: |
DIN Rail Mount |
|