- Power Cable
Page 9 of 18
Brand |
: |
RS PRO |
MFR # |
: |
773-9027 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
Current Rating |
: |
30 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
450 V, 750 V |
European Harmonised Code |
: |
H07RN-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
49 |
Size of Strands |
: |
0.24 mm |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
VDE 0285-525-2-21 |
Insulation material |
: |
EPR |
Core Strands |
: |
49/0.24 mm |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
811-4380 |
Cross Sectional Area |
: |
4 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
25 A |
Outer Diameter |
: |
11.8mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
56 |
Size of Strands |
: |
0.3 mm |
Conductor Resistance |
: |
4.95 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-50°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC Type TI1 to BS7655 |
Core Strands |
: |
56/0.3 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
11 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
491-807 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Orange |
Length |
: |
100m |
Cable Type |
: |
3182Y |
Current Rating |
: |
6 A |
Outer Diameter |
: |
7.2mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
24 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
24/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-5877 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
3182Y |
Current Rating |
: |
25 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
8.86mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
491-958 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Orange |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
15 A |
Outer Diameter |
: |
9.4mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
30 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
30/0.25 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
705-1342 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
Fire Performance |
Current Rating |
: |
19.5 A |
Outer Diameter |
: |
10.5mm |
Voltage Rating |
: |
500 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
9 mm |
Conductor Resistance |
: |
12.1 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-40°C |
Standards Met |
: |
BASEC |
Insulation material |
: |
Silicone |
Core Strands |
: |
1.5/9 mm |
Maximum Operating Temperature |
: |
+90°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
836-0701 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
4 |
Length |
: |
100m |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
12.1 → 15.5mm |
Sheath Material |
: |
Cross-Linked Compound, Type EM 8 to EN 50363-6 |
Voltage Rating |
: |
750 V |
European Harmonised Code |
: |
H07ZZ-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
45 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
Cross Linked |
Core Strands |
: |
45/0.25 mm |
Maximum Operating Temperature |
: |
+90°C |
American Wire Gauge |
: |
13 AWG |
Cable Shape |
: |
Round |
|
Brand |
: |
RS PRO |
MFR # |
: |
836-0757 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
Fire Performance |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
10.1 → 12.5mm |
Sheath Material |
: |
Thermoplastic |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05Z1Z1-F |
Number of Strands |
: |
45 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
Class 5 IEC 60228, EN 50363-7, EN 50363-8, IEC 60332-1, TS EN 50525-3-11 |
Insulation material |
: |
Thermoplastic |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-5867 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
3182Y |
Current Rating |
: |
10 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
6.39mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
19.5 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
17 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
535-985 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Outer Diameter |
: |
8mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
+5°C |
Standards Met |
: |
RoHS Compliant |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
17 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6160 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
3184Y |
Current Rating |
: |
20 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
10.63mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
773-9073 |
Cross Sectional Area |
: |
4 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
Current Rating |
: |
36 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
15.2mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
450 V, 750 V |
European Harmonised Code |
: |
H07RN-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
56 |
Size of Strands |
: |
0.286 mm |
Conductor Resistance |
: |
4.95 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
VDE 0285-525-2-21 |
Insulation material |
: |
EPR |
Core Strands |
: |
56/0.286 mm |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
11 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6094 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3182Y |
Current Rating |
: |
10 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
6.39mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
19.5 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
17 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
492-046 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3182Y |
Current Rating |
: |
15 A |
Outer Diameter |
: |
8.6mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
30 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
30/0.25 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-5883 |
Cross Sectional Area |
: |
1.25 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
13 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
7.6mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
15.51 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
16 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
863-4018 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
TRS |
Current Rating |
: |
25 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
10 → 10.6mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05RR-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
49 |
Size of Strands |
: |
0.24 mm |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
EPDM |
Core Strands |
: |
49/0.24 mm |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
863-4024 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
TRS |
Current Rating |
: |
16 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
9.5 → 9.9mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05RR-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
30 |
Size of Strands |
: |
0.24 mm |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
EPDM |
Core Strands |
: |
30/0.24 mm |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
863-4033 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
TRS |
Current Rating |
: |
20 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11.2 → 11.8mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05RR-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
49 |
Size of Strands |
: |
0.24 mm |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
EPDM |
Core Strands |
: |
49/0.24 mm |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-5873 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3182Y |
Current Rating |
: |
25 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
8.86mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
821-3248 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
5 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
12.2mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
450/750 V ac |
European Harmonised Code |
: |
H07RN-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
30 |
Size of Strands |
: |
0.3 mm |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Bare Copper |
Standards Met |
: |
VDE 0285-525-2-21 |
Insulation material |
: |
EPR |
Core Strands |
: |
30/0.24 mm |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
536-243 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
Cable Type |
: |
318-TRS |
Current Rating |
: |
13.5 A |
Outer Diameter |
: |
8.5mm |
Sheath Material |
: |
Rubber |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05RR-F |
Conductor Strand Type |
: |
Solid |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
RoHS Compliant |
Insulation material |
: |
Rubber |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
17 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
773-9051 |
Cross Sectional Area |
: |
4 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Current Rating |
: |
35 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
13.5mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
450 V, 750 V |
European Harmonised Code |
: |
H07RN-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
56 |
Size of Strands |
: |
0.286 mm |
Conductor Resistance |
: |
4.95 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
VDE 0285-525-2-21 |
Insulation material |
: |
EPR |
Core Strands |
: |
56/0.286 mm |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
11 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6185 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
5 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3185Y |
Current Rating |
: |
16 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
10.1mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
811-4365 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
2192Y |
Current Rating |
: |
6 A |
Outer Diameter |
: |
3.2 x 5.2 → 3.8 x 6.3mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V |
European Harmonised Code |
: |
H03VVH2-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
22 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-50°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
22/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6173 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
5 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3185Y |
Current Rating |
: |
10 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
8.37mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
19.5 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
17 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
536-142 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Current Rating |
: |
24 A |
Outer Diameter |
: |
10.5mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
600 V |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-10°C |
Insulation material |
: |
XLPE |
Maximum Operating Temperature |
: |
+90°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
705-1320 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
Fire Performance |
Current Rating |
: |
19.5 A |
Outer Diameter |
: |
8.5mm |
Voltage Rating |
: |
500 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
8.7 mm |
Conductor Resistance |
: |
12.1 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-40°C |
Standards Met |
: |
BASEC |
Insulation material |
: |
Silicone |
Core Strands |
: |
1.5/8.75 mm |
Maximum Operating Temperature |
: |
+90°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
821-3239 |
Cross Sectional Area |
: |
6 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
15.4mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
450/750 V ac |
European Harmonised Code |
: |
H07RN-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
84 |
Size of Strands |
: |
0.3 mm |
Conductor Resistance |
: |
3.3 Ω/km |
Conductor Material |
: |
Bare Copper |
Standards Met |
: |
VDE 0285-525-2-21 |
Insulation material |
: |
EPR |
Core Strands |
: |
84/0.29 mm |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
9 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6084 |
Cross Sectional Area |
: |
0.5 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
2192Y |
Current Rating |
: |
3 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
5.34mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V |
European Harmonised Code |
: |
H03VVH2-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
39 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
20 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
821-3235 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
8.3mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
450/750 V ac |
European Harmonised Code |
: |
H07RN-F |
Conductor Strand Type |
: |
Stranded |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
19.5 Ω/km |
Conductor Material |
: |
Bare Copper |
Standards Met |
: |
VDE 0282 |
Insulation material |
: |
EPR |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
17 AWG |
Cable Shape |
: |
Multicore |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-5895 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
25 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
9.7mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6139 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
25 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
9.7mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-5902 |
Cross Sectional Area |
: |
4 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
32 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11.17mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
4.95 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
11 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
836-0717 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
Fire Performance |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
5.9 → 7.5mm |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05Z1Z1-F |
Number of Strands |
: |
29 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
19.5 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
Thermoplastic |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
17 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
492-008 |
Cross Sectional Area |
: |
1.25 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
13 A |
Outer Diameter |
: |
8.7mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
40 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
15.5 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
40/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
16 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-5909 |
Cross Sectional Area |
: |
4 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
32 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11.17mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
4.95 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
11 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
773-9058 |
Cross Sectional Area |
: |
4 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
Current Rating |
: |
35 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
13.5mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
450 V, 750 V |
European Harmonised Code |
: |
H07RN-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
56 |
Size of Strands |
: |
0.286 mm |
Conductor Resistance |
: |
4.95 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
VDE 0285-525-2-21 |
Insulation material |
: |
EPR |
Core Strands |
: |
56/0.286 mm |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
11 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
863-4027 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
TRS |
Current Rating |
: |
6 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
7.2 → 7.6mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05RR-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
24 |
Size of Strands |
: |
0.19 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
EPDM |
Core Strands |
: |
24/0.19 mm |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
491-904 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
3184Y |
Current Rating |
: |
6 A |
Outer Diameter |
: |
8.3mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
24 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
24/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8331 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
NYM-J |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11.5mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
1.365 mm |
Conductor Resistance |
: |
12.1 Ω/km |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
HD 21.4 S2, IEC 60228 Class1, IEC 60332-1 |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|