Brand |
: |
RS PRO |
MFR # |
: |
262-3219 |
Thermocouple Type |
: |
T |
Probe Diameter |
: |
1/0.2mm |
Probe Length |
: |
2m |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Miniature Plug |
Standards Met |
: |
ANSI |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
262-3195 |
Thermocouple Type |
: |
T |
Probe Diameter |
: |
1/0.2mm |
Probe Length |
: |
2m |
Probe Material |
: |
PTFE |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Miniature Plug |
Standards Met |
: |
IEC |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
262-3222 |
Thermocouple Type |
: |
T |
Probe Diameter |
: |
1/0.2mm |
Probe Length |
: |
2m |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Miniature Plug |
Standards Met |
: |
ANSI |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
262-3199 |
Thermocouple Type |
: |
T |
Probe Diameter |
: |
1/0.315mm |
Probe Length |
: |
2m |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Miniature Plug |
Standards Met |
: |
IEC |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
262-3196 |
Thermocouple Type |
: |
T |
Probe Diameter |
: |
1/0.2mm |
Probe Length |
: |
5m |
Probe Material |
: |
PTFE |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Miniature Plug |
Standards Met |
: |
IEC |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
262-3212 |
Thermocouple Type |
: |
T |
Probe Diameter |
: |
1/0.315mm |
Probe Length |
: |
5m |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Miniature Plug |
Standards Met |
: |
IEC |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3166 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
10m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3143 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PTFE |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
2m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3179 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
1m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3142 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PTFE |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
1m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3145 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PTFE |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
5m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3163 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
1m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3181 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
5m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3146 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PTFE |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
10m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3144 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PTFE |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
3m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3155 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
1m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3156 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
2m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3157 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
5m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3158 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
10m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3164 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
2m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3165 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
5m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3182 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
10m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
271-3180 |
Thermocouple Type |
: |
T |
Probe Material |
: |
PFA |
Maximum Temperature Sensed |
: |
+250°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
XQ |
Cable Length |
: |
2m |
Standards Met |
: |
IEC 584-3 |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
268-4474 |
Thermocouple Type |
: |
T |
Maximum Temperature Sensed |
: |
+260°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
Hermetically Sealed Thermocouple |
Cable Length |
: |
2m |
Standards Met |
: |
IEC |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
268-4473 |
Thermocouple Type |
: |
T |
Maximum Temperature Sensed |
: |
+260°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
Hermetically Sealed Thermocouple |
Cable Length |
: |
1m |
Standards Met |
: |
IEC |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
268-4475 |
Thermocouple Type |
: |
T |
Maximum Temperature Sensed |
: |
+260°C |
Termination Type |
: |
Bare Wire Tail |
Series |
: |
Hermetically Sealed Thermocouple |
Cable Length |
: |
5m |
Standards Met |
: |
IEC |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
268-4476 |
Thermocouple Type |
: |
T |
Maximum Temperature Sensed |
: |
+260°C |
Termination Type |
: |
Miniature Plug |
Series |
: |
Hermetically Sealed Thermocouple |
Cable Length |
: |
1m |
Standards Met |
: |
IEC |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
268-4477 |
Thermocouple Type |
: |
T |
Maximum Temperature Sensed |
: |
+260°C |
Termination Type |
: |
Miniature Plug |
Series |
: |
Hermetically Sealed Thermocouple |
Cable Length |
: |
2m |
Standards Met |
: |
IEC |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
268-4478 |
Thermocouple Type |
: |
T |
Maximum Temperature Sensed |
: |
+260°C |
Termination Type |
: |
Miniature Plug |
Series |
: |
Hermetically Sealed Thermocouple |
Cable Length |
: |
5m |
Standards Met |
: |
IEC |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
204-8392 |
Thermocouple Type |
: |
K |
Probe Diameter |
: |
0.2mm |
Probe Length |
: |
800mm |
Maximum Temperature Sensed |
: |
450°C |
Termination Type |
: |
Miniature Plug |
Cable Length |
: |
800mm |
Cable Length |
: |
800mm |
Best Accuracy |
: |
±1.5 °C (±0.25%) |
Connector Type |
: |
Miniature Plug |
|
Brand |
: |
RS PRO |
MFR # |
: |
220-9491 |
Thermocouple Type |
: |
K |
Probe Diameter |
: |
1/0.076mm |
Probe Length |
: |
500mm |
Probe Material |
: |
Teflon PTFE |
Maximum Temperature Sensed |
: |
+260°C |
Termination Type |
: |
2-Wire Tail |
Cable Length |
: |
500m |
Minimum Temperature Sensed |
: |
-75°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
204-8391 |
Thermocouple Type |
: |
K |
Probe Diameter |
: |
7/0.2mm |
Probe Length |
: |
1.5m |
Maximum Temperature Sensed |
: |
280°C |
Termination Type |
: |
Miniature Plug |
Cable Length |
: |
1.5m |
|
Brand |
: |
RS PRO |
MFR # |
: |
200-0601 |
Thermocouple Type |
: |
K |
Probe Diameter |
: |
3.2mm |
Probe Length |
: |
4mm |
Probe Material |
: |
Nickel Aluminium, Nickel Chrome |
Maximum Temperature Sensed |
: |
+400°C |
Termination Type |
: |
Bare Wire Tail |
Cable Length |
: |
1m |
|
Brand |
: |
RS PRO |
MFR # |
: |
200-0610 |
Thermocouple Type |
: |
J |
Probe Diameter |
: |
5mm |
Probe Material |
: |
Copper |
Maximum Temperature Sensed |
: |
+350°C |
Termination Type |
: |
Bare Wire Tail |
Cable Length |
: |
2m |
|
Brand |
: |
RS PRO |
MFR # |
: |
200-0607 |
Thermocouple Type |
: |
J |
Probe Diameter |
: |
4mm |
Probe Material |
: |
Copper |
Maximum Temperature Sensed |
: |
+350°C |
Termination Type |
: |
Bare Wire Tail |
Cable Length |
: |
2m |
|
Brand |
: |
RS PRO |
MFR # |
: |
200-0612 |
Thermocouple Type |
: |
J |
Probe Diameter |
: |
8mm |
Probe Material |
: |
Copper |
Maximum Temperature Sensed |
: |
+350°C |
Termination Type |
: |
Bare Wire Tail |
Cable Length |
: |
2m |
|
Brand |
: |
RS PRO |
MFR # |
: |
200-0609 |
Thermocouple Type |
: |
K |
Probe Diameter |
: |
4mm |
Probe Material |
: |
Copper |
Maximum Temperature Sensed |
: |
+350°C |
Termination Type |
: |
Bare Wire Tail |
Cable Length |
: |
2m |
|
Brand |
: |
RS PRO |
MFR # |
: |
200-0613 |
Thermocouple Type |
: |
K |
Probe Diameter |
: |
8mm |
Probe Material |
: |
Copper |
Maximum Temperature Sensed |
: |
+350°C |
Termination Type |
: |
Bare Wire Tail |
Cable Length |
: |
2m |
|
Brand |
: |
RS PRO |
MFR # |
: |
200-0611 |
Thermocouple Type |
: |
K |
Probe Diameter |
: |
5mm |
Probe Material |
: |
Copper |
Maximum Temperature Sensed |
: |
+350°C |
Termination Type |
: |
Bare Wire Tail |
Cable Length |
: |
2m |
|
Brand |
: |
RS PRO |
MFR # |
: |
220-9490 |
Thermocouple Type |
: |
K |
Probe Diameter |
: |
1/0.076mm |
Probe Length |
: |
2m |
Probe Material |
: |
Teflon PTFE |
Maximum Temperature Sensed |
: |
+260°C |
Termination Type |
: |
2-Wire Tail |
Cable Length |
: |
2m |
Standards Met |
: |
ANSI MC96.1 |
Minimum Temperature Sensed |
: |
-75°C |
|